310 Single Solenoid Valve Series
310 sINGLE ELECTRIC (SOLENOID) VALVE
1/8 orifice — 10 CFM at 100 psig
2- or 3-way.
Two position - spring return.
Pressure rating: 0 to 125 psig.
Voltage — 12v DC, 24v DC, 24/50-60, 100/50-60, 120/50-60, 200/50-60, 240/50-60 and Low Watt (1.8) 12vDC and 24vDC
- Normally closed, normally open or as a selector or divertor, depending on port selections.
- Quiet operation with no AC hum.
- Electrical connection options include lead wires, conduit connector (order Code 36) or DIN type connector (order Code 39).
- Available with UR rating. Contact factory for more information.
- Non-locking manual override is standard. For optional locking manual override, order Code 81.
- Fast cycling — 600 CPM
- Mount in any position - inline, body mounting holes, mounting bracket or one piece manifold ( 410M ).
| Voltage | Resistance (Ohms) |
Current (Milliamps) |
| 12 VDC | 36 | 333 |
| 24 VDC | 144 | 167 |
| 24 VAC | 100 | 200 |
| 100 VAC | 2100 | 44 |
| 120 VAC | 3025 | 36 |
| 200 VAC | 8400 | 22 |
| 240 VAC | 12100 | 18 |
|
• All coils are standard with 24-inch black lead wires. Optional 72-inch lead wires are available. • All AC coils are rated for 50/60 Hertz. • All coils conform to Class B insulation systems. • Resistance and current are nominal values. • Valve assemblies are "hi-pot" tested at 1750 VAC for one second. • Ensure proper voltage supply per voltage label rating, +10%, -15% for AC or DC voltages |
||